General
YCM8 Series circuit breakers were developed according to the demand of domestic and international market as well as features of similar products.
Its rated insulation voltage up to 1000V, is suitable for AC 50Hz distribution network circuit whose rated operation voltage is up to 690V, rated operation current from 10A to 800A. It can distribute power, protect the circuit and power supply devices from the damage of overload, short circuit and under voltage, etc.
This series circuit breaker feature small volume, high breaking capacity and short arcing. It can be installed vertically (namely vertical installation) and also installed horizontally (namely horizontal installation).
It complies with standards of IEC60947-2.
General YCM7RE Series Electronic circuit breaker is suitable for ac 50 Hz, rated voltage 690V, the rated working current 800A low voltage power grid.
General
1. YCHGLZ1-125-3150A is suitable for switching two low-voltage circuits or transforming and safely isolating two load devices
2. Operating mode:
Direct operate: handle is installed on the switch
Operation outside the cabinet: handle is installed ouside of distribution cabinet door
3. 3P,4P(3P+breakable neutral pole)
4. It can be used for outside-cabinet operation with long axis
5. Two auxiliary contacts can be installed if needed
6. Electrical performance and mechanical performance is as same as YCHGL-125- 3150A correspondingly
7. Provide bridge type connecting conductors connected with output terminal or input terminal of switch
PS: when using bridge type connection, please instruct if it applies to the line end or the outlet end
YCM3 Series moulded case circuit breaker,is new products,with small compact, modular,high break,double breakpoints,zero arcing,green environmen protection.Suitable for AC 50Hz,60Hz,rated operating voltage 690V and below, rated current 12.5A to 1600A distribution network,used to distribute electrical energy and protection lines and power supply equipment from overload,short circuit and undervoltage failure hazards.It can also be used as a non-frequent conversion of the line under normal conditions and in the infrequent start of the motor.
General
The YCKG7 series time control switch is suitable for AC 50Hz,rated control powersupply voltage to AC380V control circuit,as a delay timing component.It canconnect or disconnect the power supply ofvarious control circuits according to thepredetermined time,suitable for street lights,neon lights,advertising signs,radioand television equipment,and various household appliancesStandard:IEC 60947-4-1
General
1.YCHGLZ1-125-3150A is suitable for switching two low-voltage circuits or
transforming and safely isolating two load devices
2.Operating mode:
Direct operate:handle isinstalled on theswitch
Operationoutside the cabinet handle is installedousideof distibutioncabinet door
3、3P4P(3P+breakable neutral pole)
4.It canbe used for outside-cabinet operation withlong axis
5.Two auxiliary contacts can be installed ifneeded
6.Electrical performance and mechanical performanceis as same as YCHGL-125-3150A correspondingly
7.Provide bridge type connecting conductors connected with output terminal orinput terminalof switch
PS:when using bridge type connection,please instructif it appliesto theline endor the outlet end
Features
1. Rated Current up to 40A
2. Only 9mm for 1P
3. Frameworks are 2P/4P