Product Overview
Product Details
Data Download
Related Products
Product Features
1.Sensorless vectorcontrol with the best low frequencycompensation ability
2 Designed with spedial radiator tree and switch powe,all of suchkinds of newtechnologiesimprovethe performance
3.Several protective techologies and new component have beenapplied to thecircuit,notablyimprove theanti-interferenceability
4.Realize the preset frequency.or central frequency adjustable swing frequencyfunction
5.Several phasesspeed operation controlled by build-in PLCor controllingterminal
6.ModulationMode:space vector pulbsewidthmodulationSVPWN
7.Automatic energysavingoperatiom automatically optimize V/F curve tosave theenergy
8.Switch input channet forwardand reversal roration control,8 channel programswitchinput,35 kinds offunction
9.Strong overload perfomance 150%rated corrent for 1 minute,180%ratedcurrentfor 3 seconds
10.Communication functiom RS485 standard communication interface,supportASOland RTUformat MODBUS communicationprotocol
Contact Us
1. Applied with boiler drunm, induced draft fan, coal mine ventilator, etc
2. Applied in central air-condition energy saving optimization, air compressor energy saving renovation, music fountain, etc
3. Applied with water circulating pump, water supply pump, clear water pump, sewage pump, purification pump, constant pressure water supply, oilfield water injection pump, oil pump, etc
4. Applied with mine conveyer, coal feeder, mixer, pulverizer, converter, blast furnace, etc
5. Applied with extruder, bottle blowing machine, film blowing machine, film conveying belt, centrifugal separator, compressor, sprayer, etc
Item | Item Description | |
Input | Rated voltage, frequency | Single phase 220V, three phase 200V, three phase 380V, three phase 480V; 50/60Hz |
Permissible working voltage | Effective value of voltage: 220V class 180~230V, 380V class 320~460V Voltage unbalanced rate: <3%; Frequency error: ≤+5% |
|
Output | Rated voltage | Three phases 0~input voltage |
Frequency | 0~400Hz | |
Overloading capacity | G type: 110% long term, 150% 1min, 180% 1s, 200% instantaneous trip P type: 120% 1min, 150% 1s, 180% instantaneous trip |
|
Control Function |
Working mode | Electromagnetic vector PWM modulation |
Adjustment range | 1:100 | |
Starting torque | 100% rated torque at 3Hz | |
Frequency accuracy | Digital setting: highest frequency×±0.01% Analog setting: highest frequency×±0.2% |
|
Frequency resolution | Digital setting: 0.01Hz; Analog setting: highest frequency×0.1% | |
Torque | Automatically increase the torque according to the output current. Manually rise torque up, scope:1~30% |
|
V/F curve | 1. Linear curve 2. Square curve |
|
Acceleration, slow-downtime | 0.1~6000s/min continuous adjustment. | |
Compensation for rotation error | Setting scope: 0~20%, it can auto adjust the output frequency of inverter according to the motor loading, to reduce speed changes caused by motor load fluctuations. |
|
Built-in PID | Easily form the loop control system, which is suitable for pressure control, flux control and etc. |
|
Auto voltage regulation | When network voltage change, it can auto adjust the output of PWM and keep output voltage constant |
|
Auto energy-saving run | As load change, it auto optimize the V/F curve, to realize the energy-saved running. | |
Running Function |
Frequency setting | The setting of Potentiometer in the panel: operation panel / key setting, terminal of outer control Rise / Drop setting, ananlog voltage signal or outer potentiometer setting, analog current signal setting, ananlog combination setting, setting of 485 serial communication. |
Running command | Control of operation panel, control of outer terminals, control of serial communication | |
Analog output terminal | 0~10V DC voltage signal output, can realize the output of frequency, current and etc, physical parameters |
|
Input signal | Positive/megative rotation signal, multi-step signal, fault signal, reset signal | |
Output signal | Programmable integrated circuit opening output, fault signal output |
Item | Item Description | |||
Braking Function |
Braking by power consumption |
External braking resistor, maximum braking torque 100% | ||
Brake by direct current | When starting or stopping, it is optional respectively, action frequency: 0-20Hz, action voltage level: 0-20%,action time 0-30s, continuously adjustable |
|||
Other Functions | Jumping frequency, point function, counter, rotation speed track, restart after instan-staneous power off, upper and lower frequency limit, acceleration and slow-down modes adjustable, cymometer and voltmeter output, multi-step / program running, two lines / three lines control, double polar control, selection of multifunctional input terminal, auto reset after fault, 485 serial communication |
|||
Protection Function | Input protection against phase failure, over-current protection, overloading protection, under-voltage protection, overheating protection, output short circuit protection and etc. |
|||
LED Display | It can display real-time working status, monitoring parameters, function data, fault codes and etc of the inverter |
|||
Optional Accessories | Braking parts, remote and operation panel and connection wire, communication panel | |||
Ambient Conditions |
Working site | Indoor, without direct sunshine, no dust, corrosive gas, flammable and explosive gas, oil fog, steam, water drop, salty |
||
Altitude | Altitude less than 1000m | |||
Ambient temperature | -10-+45℃ (The only machine: -10~+50℃) | |||
Humidity | 20~90%RH, Without water condensation | |||
Vibration | <0.5G | |||
Storage temperature | -20~+60℃ | |||
Protection grade | IP20 | |||
tructure | Cooling mode | Fan cooling | ||
Mounting mode | Wall hung type, standing type |
Item | Item Description | |
Braking Function |
Braking by power consumption |
External braking resistor, maximum braking torque 100% |
Brake by direct current | When starting or stopping, it is optional respectively, action frequency: 0-20Hz, action voltage level: 0-20%,action time 0-30s, continuously adjustable |
|
Other Functions | Jumping frequency, point function, counter, rotation speed track, restart after instan-staneous power off, upper and lower frequency limit, acceleration and slow-down modes adjustable, cymometer and voltmeter output, multi-step / program running, two lines / three lines control, double polar control, selection of multifunctional input terminal, auto reset after fault, 485 serial communication |
|
Protection Function | Input protection against phase failure, over-current protection, overloading protection, under-voltage protection, overheating protection, output short circuit protection and etc. |
|
LED Display | It can display real-time working status, monitoring parameters, function data, fault codes and etc of the inverter |
|
Optional Accessories | Braking parts, remote and operation panel and connection wire, communication panel | |
Ambient Conditions |
Working site | Indoor, without direct sunshine, no dust, corrosive gas, flammable and explosive gas, oil fog, steam, water drop, salty |
Altitude | Altitude less than 1000m | |
Ambient temperature | -10-+45℃ (The only machine: -10~+50℃) | |
Humidity | 20~90%RH, Without water condensation | |
Vibration | <0.5G | |
Storage temperature | -20~+60℃ | |
Protection grade | IP20 | |
tructure | Cooling mode | Fan cooling |
Mounting mode | Wall hung type, standing type |
YCB1000/380Vthree phase | Appearance Size (mm) L ×W × D |
Aperture Size of Panel (mm) L × H |
||||||||
No. | Model | Power | Voltage | |||||||
1 | YCB1000 | 0.75kW | 380V | 169 × 125 × 170 | Panel: 75 ×55 Panel Cover: 95 ×61 |
|||||
2 | 1.5kW | |||||||||
3 | 2.2kW | |||||||||
4 | 4kW | |||||||||
5 | 5.5kW | 245 × 150 × 188 | Panel: 93 ×70 Panel Cover: 131 ×91 |
|||||||
6 | 7.5kW | |||||||||
7 | 11kW | 320 ×220 ×210 | Panel: 131 ×70 Panel Cover: 156 ×80 |
|||||||
8 | 15kW | |||||||||
9 | 18.5kW | 395 ×260 ×215 | ||||||||
10 | 22kW | |||||||||
11 | 30kW | |||||||||
12 | 37kW | 520 ×290 ×290 | ||||||||
13 | 45kW | 570 ×290 ×280 | ||||||||
14 | 55kW | |||||||||
15 | 75kW | 600 ×325 ×310 | ||||||||
16 | 93kW | |||||||||
17 | 110kW | 630 ×380 ×380 | ||||||||
18 | 132kW | |||||||||
19 | 160kW | 880 ×510 ×400 | ||||||||
20 | 185kW | 980 ×510 ×400 | ||||||||
21 | 200kW | |||||||||
22 | 220kW | |||||||||
23 | 260kW | 1050 ×710 ×420 | ||||||||
24 | 280kW | |||||||||
25 | 315kW | |||||||||
26 | 350kW | |||||||||
27 | 400kW | 1200 ×860 ×400 | ||||||||
28 | 500kW |
YCB1000/220V single phase | Appearance Size (mm) | Aperture Size of Panel (mm) | |||||||||
No. | Model | Power | Voltage | L ×W × D | L × H | ||||||
1 | YCB1000 | 0.75kW | 220V | 142 ×85 × 122 | Panel: 140 ×73 Panel Cover: 175 ×87 |
||||||
2 | 1.5kW | ||||||||||
3 | 2.2kW | 185 ×96 × 150 |