General
Function description:Whena phase of L1,L2,L3 overvoltaged,undervoltaged orphase lacked,the relaywill be disconnected andautomatically search for the normalphase,and switch to open the relay of the normal phase,switching priority
L1>L2>L3!
The Signal Lamp is applicable to circuit with rated voltage 230V~and frequency 50/60Hz for visual indication and signaling.
General
The Modular Voltage Meter is applicable to circuit with rated frequency 50/60Hz for measure and display digital voltage.
Standard: IEC 60051-1
General
1. YCCH6/YCCH7 series AC contactor (hereinafter referred to as the household appliances control a contactor) is used for remote switch on and off without a sense of feeling or low load, resistance furnace, household appliances and similar low load, motor and other household.
2. The main contactor is used in AC 50Hz/60Hz, rated voltage to 400V, rated current of power system to 100A, AC-1, AC-7a (in no sense or sense of low load, resistance furnace, household appliances and similar low load) categories, long distance switch and control circuit.
3. Contactor is not used for breaking short circuit current, so it is necessary to choose suitable short circuit protection electrical equipment.
General
YCCH6Z series AC contactor (hereinafter referred to as the household
appliances control a contactor) is used for remote switch on and off without a
sense of feeling or low load, resistance furnace, household appliances and similar low load, motor and other household.
The main contactor is used in AC 50Hz/60Hz, rated voltage to 400V, rated current
of power system to 100A, AC-1, AC-7a (in no sense or sense of low load,
resistance furnace, household appliances and similar low load) categories, long distance switch and control circuit.
Contactor is not used for breaking short circuit current, so it is necessary to choose suitable short circuit protection electrical equipment.
Standard: IEC/EN 61095
General
1.YCCH6/YCCH7 series AC contactor (hereinafter referred to as the household appliances control a contactor)is used for remote switch on and off without a sense of feeling or low load,resistance furnace,household appliances and similar lowload,motor and other household.
2.The main contactor is used in AC 50Hz/60Hz,rated voltage to400V,rated current of power system to 100A,AC-1,AC-7a (in no sense or sense of low load, resistance furnace,household appliances and similar low load)categories,long distance switch and control circuit.
3.Contactor is not used for breaking short circuit current,so it is necessary to choose suitable shortcircuit protection electrical equipment.